Official question bank for guided preparation.
#1
What is the minimum permitted clear height in the under-stair space?
Model answer key: 2.05 m. Always verify the currently adopted AD/BC documents before use.
View question#2
Minimum distance between a private residential villa swimming pool and a safety fence/barrier.
Answer key: 1 m. Verify in local pool barrier rules.
View question#3
Maximum plot/building area ratio (coverage) for buildings with several separated non-residential and mixed uses, per the practice key.
Answer key: 1.00. Confirm the correct interpretation (FSI vs. coverage) with the official code.
View question#4
In building regulations, a light well / light court is best described as which option?
Option (c) is marked correct in the source model.
View question#5
What is the minimum width of a shared access route in staff work areas of an office/employer zone?
Key: 1.2 m
View question#6
Maximum site/building coverage in Abu Dhabi **industrial** zoned land (per the answer key: 65%).
Key: 65% of the plot. Confirm the latest industrial-plot coverage in official tables.
View question#7
For parking that serves a public facility, where should the accessible parking sit relative to a walking route/entry? (per key: near accessible pedestrian access point).
Key: option (A).
View question#8
Which design element concerns the tactile/texture quality of a material surface in architecture? (Key: texture.)
Answer: (B) texture.
View question#9
Visible basement projection: **50% of basement *headroom* or 1.85 m, *whichever is less*** — same *policy line* as 2A-63; **DRAFT** for dedupe, not a second public *slug* on the same rule.
Draft. Pure policy duplicate; keep 2A-63 as the *canonical* public question.
View question#10
Design principle: visual weight balance?
Key: B (balance).
View question#11
Code bundle for life-safety / means of egress in key?
Key: D.
View question#12
When is accessible path required in key?
Key: A.
View question#13
Max guest-annex height in setback (key)?
Key: D 6m.
View question#14
Steel coating spec in key?
Key: C AISC 360.
View question#15
Min 2nd extra bedroom m² in key?
Key: D 14m².
View question#16
Tactile warnings at? (key)
Key: B.
View question#17
Open wall % for >9m² annex in key?
Key: C 10%.
View question#18
R-2 party separation type (key)?
Key: C fire separation.
View question#19
In an escape path, what portion of the ceiling’s area may be reduced in height for services/protrusion (per the source key, 25%)?
Key: 25% — verify the exact DMT/AD corridor/MEP text.
View question#20
Element = dimensions in key?
Key: C form.
View question#21
Count in key for 151-200 unit building?
Key: D 8.
View question#22
Villa path min width in this model key?
Key: D 1.0; note other models may say 1.2m.
View question#23
Pool barrier min height in key?
Key: C 1.2m.
View question#24
Max nosing (cm) in M5 key?
Key: B 3.2cm.
View question#25
FAR Asharej in key?
Key: D 3.9.
View question#26
Anti-panic device in key (phrasing).
Key: D.
View question#27
Permitted handrail / barrier height **range (cm) at stairs, per the source key: 86.5–96.5 cm (top of nosing/riser reference per sheet).
Key: (D).
View question#28
Key ratio for 150 self-storage context?
Key: A 10%.
View question#29
Min lines for 9-15 aisle context?
Key: C 3.
View question#30
Min curing in key?
Key: C 7 days.
View question#31
How many of 4 entries must be accessible in key?
Key: B 2.
View question#32
F-rating in systems mainly means? (D)
Key: D.
View question#33
Min living area efficient unit in key.
Key: D 20.5m².
View question#34
Rooftop mech/utility cap downtown Al Ain in key?
Key: A 3.5m; compare 4.0m lines.
View question#35
Type I structure — FRR for the main load-bearing frame (per key: 3 h).
Key: 3 h. Confirm the building type in your exam sheet is Type I as printed.
View question#36
Door swing: half of *actual* clear width? (C)
Key: C.
View question#37
Main bedroom min m² in this model key?
Key: B 16; compare 18m² in other model.
View question#38
Annex on plot wall: key?
Key: C if compliant.
View question#39
Pool safety: key (C).
Key: C.
View question#40
Industrial lot coverage in key.
Key: B 65%.
View question#41
Min m² for natural vented service room?
Key: A >9m².
View question#42
Accessible seats % in assembly key?
Key: C 5%.
View question#43
Industrial ground floor lift in key (cm).
Key: D 45cm.
View question#44
Another model: min 2 (C) — near-dup allowed.
Key: C 2; near-dup for coverage.
View question#45
Visible basement: whichever less (A) in key.
Key: A (whichever less).
View question#46
Thermal performance required for an annex: match the main villa, lower, higher, or not required? (per key: same as main villa).
Key: (C).
View question#47
Which use level cannot be under others in key?
Key: B res per extract.
View question#48
Secondary use max m in ind. plot key?
Key: B 8m.
View question#49
Roof service visibility/coverage rule (D) in key.
Key: D.
View question#50
Design element: light (C).
Key: C.
View question#51
Max built % residential plot in key.
Key: D 70%.
View question#52
Design phase: programming (B).
Key: B programming.
View question#53
Principle with proportion? (C)
Key: C.
View question#54
In a mixed commercial building, which floor type the practice key marks as the “top of stack” (no other uses on top) — the source marks **(A) residential** as the key answer (interpret the exam diagram carefully in context).
Context-heavy item — cross-check the PDF diagram. Key from dump: (A).
View question#55
Open walk roof: no guard if height ≤? (B 550 in extract 2440-2441).
Key: B 550mm.
View question#56
Maximum allowed roof / roof-level built area as a share of the roof (per key: 60%).
Key: 60%.
View question#57
If the annex is on the street front plot boundary, what is the setback principle? (Key: direct build **subject to conditions**).
Key: (C).
View question#58
Maximum vertical travel in one stair **run** before a landing is required (per key: 3.65 m).
Key: 3.65 m.
View question#59
Definition of **road axis level** (per key: centreline of the road at the main plot entry).
Key: (A).
View question#60
Protection for decorative façades in **R2** housing (per key: automatic sprinkler protection for the scenario in the sheet).
Key (C) — verify detailed R2 rule in the current official code.
View question#61
Minimum **% of fixed/built-in seating** that must be accessible (per key: 5%).
Key: 5%.
View question#62
Type V building: FRR for roof and secondary elements (per key: 1 h).
Key: 1 hour.
View question#63
Which occupancy is **exempt** from certain access requirements in the key? (Single-occupant tunnel / subsurface access scenario from the sheet.)
Key (C) — wording is exam-specific.
View question#64
Maximum **height of a villa building** in the key set (per answer key: 18 m).
Key: 18 m — check latest zone rule.
View question#65
Max height of the main industrial activity block on an industrial lot (per key: 10 m).
Key: 10 m.
View question#66
On how many sides must a stair provide handrails/guards? (per key: **two sides (d)** for the scenario in the key).
Key: (D).
View question#67
What is the maximum height for a stair guard (balustrade) in the key set?
Key: 96.5 cm. Verify the reference in the current adopted AD building code / exam sheet note.
View question#68
Purpose of the command / fire-control centre in high-rise facilities (per key: civil defense coordination).
Key: civil defense / emergency services coordination (context term may vary; verify the sheet wording).
View question#69
Which building type the key marks for an accessibility **exemption**? (Key: single-occupant access via an underpass / tunnel).
Key (D).
View question#70
Al Ain commercial-plot: allowed number of storeys in the key (basement + 3 + ground).
Key (B) — verify the exact “centre/zone” name on your PDF.
View question#71
Permitted use of the ground floor on an industrial-plot: key marks one office + industrial or storage (option C).
Key (C).
View question#72
Minimum separation distance between buildings on a **commercial** plot, per the model key: 2 m (D).
Key: 2 m.
View question#73
Required handrail **height range** in Model 2 key: 75–85 cm. (Note: Model 1 M1#12 used a different range — discipline editors should reconcile with official code.)
M2 key: (A). Cross-check for **guard** vs **hand** rail definitions.
View question#74
Minimum finished floor level of the **ground** storey in **industrial** zoned land (per key: 45 cm).
Key: 45 cm. Verify the datum reference in the current industrial plot notes.
View question#75
Minimum **width** of access paths within a private residential **plot** in the key (1.2 m).
Key: 1.2 m.
View question#76
How many internal stairs (stairways) are allowed in a **villa** to connect floors, per the model key: **two** (D).
Key (D). Pair with M1#8 — validate villa stair count rule in the official PDF you hold.
View question#77
Minimum first-aid **room** area in an **industrial** plot, per the key: 7 m².
Key: 7 m².
View question#78
Minimum distance from a coastal line / set-back (per the model key, **approval by the competent authority** is the “measure” in the set).
Key (C) — often authority-driven, not a single static number in all coastal contexts.
View question#79
Max height of **rooftop** services/structures in **downtown** Al Ain commercial sub-zone (per key: 4 m).
Key: 4 m. Confirm the named sub-zone in your PDF (urban centre wording).
View question#80
Minimum **finished clear** headroom/height in the **basement** level in **industrial** buildings (per key: 3.0 m).
Key: 3.0 m.
View question#81
Minimum **daylighting** (glazing) ratio / opening area relative to the relevant floor area in the model key: **10%**.
Key: 10% — the exam uses a specific clause reference; read the table context in the PDF if attached.
View question#82
Which areas need **detectable** warning surfaces/edges (hazard marking), per the key: **passenger pick-up / platform edges (boarding edges)** (option C in this dump).
Key (C) — compare accessibility chapter “hazard and boarding edge” notes.
View question#83
How many internal stairways are allowed in a villa to connect floors? (per model key).
Key: two. Cross-check the villa internal stair rule in your PDF (pairs with the “two internal stairs” item).
View question#84
Per the key: minimum nosing + rise pairing for a stair (28 cm + 3.2 cm option set).
Key (D).
View question#85
With habitable space in a basement, which element is required? (per key: outdoor means-of-egress / rescue).
Key (A).
View question#86
Maximum coverage ratio for multi-use buildings in this key set (1.00).
Key: 1.00 — confirm whether the exam references GFA factor vs. lot coverage in your adopted tables.
View question#87
Basement entrance level vs. street: requirement to prevent water ingress (key: must be **above** street).
Key (D).
View question#88
A “tall/ high” building, per this exam sheet, has occupied storeys at a height of more than **23 m**.
Key: 23 m. Match the **exact definition text** the exam booklet defines for “high” buildings.
View question#89
Minimum distance between the main residential villa and accessory buildings, per the key: **1.5 m**.
Key: 1.5 m.
View question#90
The “main / primary street” is: **as adopted in the detailed master plan** (per key, option B).
Key (B). It references the plan-approved street, not a guess from plot orientation alone.
View question#91
Permitted **ground** floor use on commercial zoned land in the **Jimi (Al Ain) context** in this answer key.
Key (D). The exam names a **local commercial sub-district in Al Ain (Jimi)**, not Dubai. Verify your PDF’s exact sub-zone name.
View question#92
Minimum **internal** clear height in accessory buildings, per the model key: **3.0 m**.
Key: 3.0 m. Cross-check the Arabic definition (clear height to slab/soffit).
View question#93
Maximum **visible** basement projection above the ground: **50% of basement height *or* 1.85 m, whichever is less** (per key B).
Key (B).
View question#94
Steepest ramp slope ratio allowed in the key set (**1:12**).
Key: 1:12 as the **steepest** value in this set. This differs from the “10:1 minimum slope is false” item — keep both in mind.
View question#95
If the basement extends **beyond the plot** plan profile, the key demands **at least 40%** in the test wording.
Key: ≥ 40% — the Arabic stem refers to basement projection beyond the site boundary.
View question#96
Maximum **overall** stair / flight width the key lists for this exam: **1.5 m**.
Key: 1.5 m (overall stair width) — not the same as guard/ handrail *height* items.
View question#97
Minimum area of the **main living** space (per key: 20 m²).
Key: 20 m²
View question#98
Maximum unguarded open walk / level change (per the answer key) before a **guard** is **required**: **760 mm**.
Key: 760 mm. Compare with *guard height* and *ramp* questions: different clauses.
View question#99
Which design phase is about broad visioning and initial ideas? (per key: **concept** design / schematic ideation).
Key: conceptual / schematic. Not final DD/CD documentation.
View question#100
Minimum **setback** from the street frontage plot line, per the model key: **2.0 m**.
Key: 2.0 m. Always compare with the **setback to street vs. to neighbour** items — different clauses.
View question#101
Construction type 5B: the key says **all listed materials are permitted** in the test framing.
Key (D). Tied to the “Type 5B” scenario in the mock exam.
View question#102
For **Al Ain commercial-plot** basements, the key’s allowed utility bundle includes storage + MEP/utility cores + car parking (as listed in the sheet’s option B).
Key (B). A long “bundle of uses” in Arabic — the exam expects you to read the *exact* sub-zone in your PDF (Al Ain), not a generic “any basement”.
View question#103
Villa main entrance: one accessibility item in the key is a **1:12 ramp** to the main entry condition.
Key: 1:12 ramp. Do not confuse with *on-plot service path* width in another line item.
View question#104
Minimum **kitchen** area and minimum wall dimension, per the key: **12 m² and 3.0 m** (option D in this set).
Key: 12 m² and 3.0 m. A parallel row in the dump shows **2.8 m** — that is a different “(alternate) version” in the same PDF. Verify which your training paper follows.
View question#105
Minimum **storey** clear height (other than the under-stair zone), per this key: **3.0 m**.
Key: 3.0 m. Not the 2.05 m *under-stair* rule — different clause type.
View question#106
Is worker housing in **industrial-plot** areas of Abu Dhabi allowed? (Key: **Yes, with specific restrictions/permits** — option D, not a blanket no).
Key (D). Beware: option (B) in the OCR dump is broken across lines. Trust the *approved official land-use* note, not a screenshot-only value.
View question#107
On **commercial-plot** land, which activity bundle is the correct broad answer? (key: a mixed set including retail, residential, admin, parking, services, leisure).
Key (A). A common classroom trap is choosing “agriculture only / industrial only” for *commercial* zoning.
View question#108
When multiple **WC compartments** are grouped, at least one rule is expressed in the key as a **10%** ratio in the test sentence.
Key: 10%. The Arabic phrasing in the group dump is a bit long — keep the 10% figure tied to *clustered* WC count rules.
View question#109
In which (IBC/AD) chapter/section is **wood construction** typically referenced in this key set? (B: 2304).
Draft. Pure code-number recall — verify which AD/EBC/IBC *edition* the exam year references.
View question#110
Which timber/grade is marked as the **treated/rot-resistant** pick in the training key (C in the group dump, Arabic trade name is noisy in OCR).
Draft. OCR garbled a trade name — re-open the page photo for the *exact* material label the exam used.
View question#111
Art. 402 (covered+open retail centres): the key’s “nonconforming/exceptional” phrasing in the Arabic dump (Option C) — re-read the PDF; language is a training trap — **DRAFT** only.
Draft. Long code sentence — not safe for a published “one-liner” without the exact regulatory Arabic from the 402 paragraph.
View question#112
Test method used to demonstrate **non-combustibility** in the key (ASTM E136, per training sheet; do not read this as a site-test procedure).
Draft. Lab-index recall item — not a public “adopted in ADM web page” one-liner without the exam table.
View question#113
Max **villa** height in Abu Dhabi (key: 18 m) — *duplicate* with an already-published 2A row → **DRAFT** to avoid a second *live* “same” question.
Draft: duplicate of an existing published villa-height entry — keep for audit trail, do not re-publish the same *slug topic* to the public set.
View question#114
Minimum separation villa ↔ accessory: **1.5 m** — *duplicate* of 2A-59 key numbers → **DRAFT** to avoid a second *live* duplicate.
Draft. Same 1.5 m rule as 2A-59 with slightly different Arabic stem — not for public duplicate count.
View question#115
How many sides of a stair need handrails/continuous grasp (key: two sides) — *duplicate* of 2A-29 → **DRAFT** (merge story).
Draft. Same *two-side handrail* idea as 2A-29 — keep a single canonical public Q.
View question#116
Storey count in **downtown** Al Ain **commercial-plot** key (3+G+bas) — *duplicate* of 2A-35 → keep **DRAFT** to avoid a second *live* repeat.
Draft. Direct overlap with 2A-35’s downtown Al Ain cap — keep a single *published* one.
View question#117
**Basement** clear height in **industrial** buildings: 2.8 m in *Model-4* key — conflicts with 3.0 m in another key row → **HOLD: internal editorial reconciliation** (draft).
Draft. Model-to-model number clash — the public set must *not* show 2.8 vs. 3.0 for the *same* clause without an editor footnote to the adopted rulebook.
View question#118
Min vertical lift between **FFL and sidewalk** in **commercial-plot** projects (per local exam key: 25 cm). **HOLD until editor reconciles the street datum definition** (draft).
Draft. Sidewalk vs. road *datum* is zone-specific. Needs a *single* public narrative before publishing to avoid misleading owners.
View question#119
Max **secondary-activity** building height in **industrial-plot** per Model-4 key: **8 m** — *may* differ from 10 m in the **main**-activity Q — **HOLD: editorial compare** (draft).
Draft. Distinguish *secondary* vs. *main* height caps. Cross-compare 2A-27/2A-47 before publishing a single *public* rule-of-thumb number.
View question#120
Min finished floor of **workshop/office** in **industrial-plot** (key: 45 cm) — **same 45** as 2A-41; keep **DRAFT** to avoid a second *public* 45-cm *near-duplicate*.
Draft. Same numeric lift as 2A-41 but different *Arabic* stem — one live entry is enough until editors separate “office+workshop FFL” by zone.
View question#121
Max **self-storage** “accessible” units in a 250-tenant facility, per a group key (16). *Sensitive numeric rule* — DRAFT until an authority table is cited in `source_notes`.
Draft. Needs the **table scan** of the *official* self-storage and accessibility code row — not just the WhatsApp key.
View questionEngHub assistant